• +90 216 469 10 78     |    +90 (533) 968 29 94-95
  • [email protected]
logo
  • Homepage
  • Company
    • About Us
    • Our Certificates
    • Our Quality Policy
    • News
    • KVKK
      • Illumination Text
      • Privacy Policy
      • Cookie Policy
  • Systems
    • ALL SYSTEMS
    • GAS EXTINGUISHING SYSTEMS
      • HFC-227ea / FM-200® Suppression System
      • HFC-125™ Suppression System
      • CO₂ Suppression System
      • FK-5-1-12 (Novec™ 1230) Suppression System
      • Argon (Inert) Suppression System
      • Suppression System Inside Panel (Micro)
    • FIRE and GAS DETECTION SYSTEMS
      • Fire Detection & Alarm System
      • Gas Detection & Alarm System
      • Ex-proof Systems
    • FOAM SUPPRESSION SYSTEMS
      • Foam Concentrations
      • Foam Sprinkler Systems
      • Foam Generators
      • Manuel Foam Systems
    • WET and DRY CHEMICAL SUPPRESSION SYSTEMS
      • Lithium Quenching System (LQS)
      • Kitchen Hood System
      • Dry Chemical Powder Systems
      • Dry Chemical Powder (DCP)
    • WATER SUPPRESSION SYSTEMS
      • Watermist Suppression System
      • Spray Cooling System
      • Fire Pumps
      • Sprinkler Suppression System
      • Fire Cabin and Hydrant System
    • PASSIVE PROTECTION SYSTEMS
      • Fire and Smoke Curtains
      • Fire Doors
      • Ventilation Covers
      • Fire Walls
      • Fire Barriers
    • PORT AND SHIPYARD FIRE SAFETY
      • Port Fire Safety
      • Shipyard Fire Safety
  • Services
    • All Services
    • Consultancy Services
    • Engineering & Project Services
    • Assembling, Comissoning & Tests
    • Maintenance & Refilling
    • Theoretical / Practical Trainings
  • Reference Projects
    • Completed Projects
    • Ongoing Projects
  • Contact
  • Turkish
  • Russian
logo
  • Homepage
  • Company
    • About Us
    • Our Certificates
    • Our Quality Policy
    • News
    • KVKK
      • Illumination Text
      • Privacy Policy
      • Cookie Policy
  • Systems
    • ALL SYSTEMS
    • GAS EXTINGUISHING SYSTEMS
      • HFC-227ea / FM-200® Suppression System
      • HFC-125™ Suppression System
      • CO₂ Suppression System
      • FK-5-1-12 (Novec™ 1230) Suppression System
      • Argon (Inert) Suppression System
      • Suppression System Inside Panel (Micro)
    • FIRE and GAS DETECTION SYSTEMS
      • Fire Detection & Alarm System
      • Gas Detection & Alarm System
      • Ex-proof Systems
    • FOAM SUPPRESSION SYSTEMS
      • Foam Concentrations
      • Foam Sprinkler Systems
      • Foam Generators
      • Manuel Foam Systems
    • WET and DRY CHEMICAL SUPPRESSION SYSTEMS
      • Lithium Quenching System (LQS)
      • Kitchen Hood System
      • Dry Chemical Powder Systems
      • Dry Chemical Powder (DCP)
    • WATER SUPPRESSION SYSTEMS
      • Watermist Suppression System
      • Spray Cooling System
      • Fire Pumps
      • Sprinkler Suppression System
      • Fire Cabin and Hydrant System
    • PASSIVE PROTECTION SYSTEMS
      • Fire and Smoke Curtains
      • Fire Doors
      • Ventilation Covers
      • Fire Walls
      • Fire Barriers
    • PORT AND SHIPYARD FIRE SAFETY
      • Port Fire Safety
      • Shipyard Fire Safety
  • Services
    • All Services
    • Consultancy Services
    • Engineering & Project Services
    • Assembling, Comissoning & Tests
    • Maintenance & Refilling
    • Theoretical / Practical Trainings
  • Reference Projects
    • Completed Projects
    • Ongoing Projects
  • Contact
  • Turkish
  • Russian

  

  • Home  
  • Spray Cooling System

View Download System Brochure

System Brochure.pdf

Quick Quote Information Get

Spray Cooling System

Designs, sellings and assemblings, maintenances done by our company on tank cooling system, which’s spray nozzles, dominant valves and cork nozzles used on tank top are imported.

The cooling system is applied according to NFPA 750 regulations on spray nozzles spraying at 110 – 165 ° angle on the outer surfaces of overground steel tanks where all flammable and combustible flammable liquids are present and mushroom nozzles spraying 360 ° at top of tank. Hydraulic calculations and application projects are done by our engineering department, and applications and tests are done by our field staff. The cooling system is designed to operate manually or automatically and valve groups are selected according to the system model.

TSE approved, stitched galvanized pipes and fittings are used unless customers do not request any alternative. Pipe connections are made of 2 “or less diameters of threaded. In case of more diameters than 2’’, pipe connections are made as grooved and welded. Our manufactures are CE certified.

Tank-Sogutma-1
Tank-Sogutma-2
Tank-Sogutma-3

Certificates

EN, TPED/EN, CE

logo
Refleks Yangın Guvenlik Sistemleri A.S., has an organization that provides design, supply, manufacturing, installation, maintenance and training of active and passive automatic fire safety systems. The concept of our company is to design via certificated software, produce and / or procure certified systems, assemble, train and maintain, and provide turnkey solutions for fire safety.

Contact Information

[email protected]

+90 216 469 10 78

+90 (533) 968 29 94-95

Cumhuriyet Mah. Abdi İpekçi Cad. Mermer Sokak No:2 Pk. 34876          Kartal / İSTANBUL

Weekday: 08:30 – 18:30

Locations

Map Image

 

Austria Russia Ukraine

Bulgaria   Belarus Pakistan

Georgia Egypt Iraq

Saudi Arabia Iran Yemen

Sri Lanka Bangladesh

© 2025 All Rights Reserved. Refleks Fire Safety Systems Inc.